Soft-db Opus Suite Intensity Module Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Audio Soft-db Opus Suite Intensity Module. Soft dB Opus Suite Intensity Module User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 26
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Opus Suite
Intensity Module
User Guide v1.4
2013-01-07
Alto 6-Channel
Concerto 4-Channel
I-Track 6-Channel
Compatible Hardware:
Soft dB Inc.
1040,
Belvedere Avenue, Suite 215
Quebec (Quebec) Canada G1S 3G3
Toll free: 1
-866-686-0993 (USA and Canada)
Zobrazit stránku 0
1 2 3 4 5 6 ... 25 26

Shrnutí obsahu

Strany 1 - Opus Suite

Opus Suite Intensity Module User Guide – v1.4 2013-01-07 Alto 6-Channel Concerto 4-Channel I-Track 6-Channel Compatible Hardware: Soft dB Inc. 1040,

Strany 2 - CONTENTS

8 4.4 File Info File Info This area displays relevant information about the current file. It also contains controls allowing to go to the previous

Strany 3 - 1 Introduction

9 5 Setup Input Setup These controls allow selecting the microphone spacer, input channel, the input type and the input range from drop down lists

Strany 4 - 2 Compatible Hardware

10 5.1 Calibration Process The calibration process includes the amplitude calibration of microphones, a phase check and a PI Index check. The amplit

Strany 5 - 3 Opus Environment

11 5.1.2 Phase Check To perform phase check: 1. Connect the intensity calibrator to the output 1 of the Concerto. 2. Insert both microphones calib

Strany 6

12 6 Explorer Dialog Explorer Window Controls and Indicators File/Folder Operators • Go to parent directory • Open directory • Create new folde

Strany 7 - 4 Main Interface

13 7 File Manager The File manager is used to perform most file operations: • Navigate the directory structure • Create folders • Rename files an

Strany 8 - 4.2 Measure Info

14 Directory Path Displays the path of the active directory. Shortcuts Allows easy access to common directories. When the File Manager is used on a s

Strany 9 - 4.3 Menu Bar

15 Appendix 1: Concerto Hardware Connections 4 Inputs Mic Stand DC in ¼ 20 insert Power-on button Second Battery 2 Outputs USB port Right click

Strany 10 - 4.5 Display Area

16 Power on/off Turn On Press the trigger button located at the back of the unit This key has two (2) functions: 1. To turn the unit ON. 2. Start

Strany 11 - 5 Setup

17 Power Reset If the Concerto happens to crash and it is not possible to take back the control, a power reset might be necessary. To complete the po

Strany 12 - 5.1 Calibration Process

i CONTENTS 1 Introduction ...

Strany 13 - 5.1.3 PI Index Check

18 Inputs and Signal Processing Specifications (Embedded Signal Ranger MK3 DSP Board) DSP Processor Texas Instruments TMS320C6424 Inputs 4 Outputs 2

Strany 14 - 6 Explorer Dialog

19 Appendix 2: 1/3 Octave Filters – IEC 61260 Class 1/ANSI S1.11 1/3 Octave Filters The 1/3 octave filters are computed at low-level in real time (at

Strany 15 - 7 File Manager

20 Shape Test Numerical Results at 1 kHz The following table presents the numerical results of the shape test at 1 kHz: Frequency (Hz) Low limit (dB)

Strany 16

21 1/3 Octave Filter Linearity The linearity of the 1/3-octave filter has been measured for both ranges (low and high). The experimentation is done w

Strany 17

22 Frequency (Hz) Saturation Level (dB) Minimum Linear Level (dB) Linear Dynamic Range (dB) Noise Floor (dB) 12500 120.5 27.0 93.5 17.5 16000 120.5

Strany 18

23 Frequency (Hz) Saturation Level (dB) Minimum Linear Level (dB) Linear Dynamic Range (dB) Noise Floor (dB) 10000 132.5 33.5 99.0 23.5 12500 132.5

Strany 19

24 Summation Test (High Range Case)-0.5-0.4-0.3-0.2-0.100.10.20.30.40.510 1001000 10000 100000Frequency (Hz)Amplitude dB

Strany 20

1 1 Introduction Congratulations on your purchase of the Opus Suite Intensity Module. The Opus Software Suite is a Sound and Vibration software that

Strany 21 - Attenuation dB

2 2 Compatible Hardware Every hardware option has an embedded state of the art Soft dB SR-MK3 DSP board allowing real-time and precise measurement w

Strany 22

3 3 Opus Environment The Concerto unit comes equipped with the Opus Environment. This environment acts as a main interface that gives access to t

Strany 23

4 The Quit button will quit the application differently according to the hardware used. Concerto hardware: • Hold 5 sec to shut down the unit. • P

Strany 24

5 4 Main Interface The main interface is divided into five sections: 1) Measure controls (see section 5.1, p. 6) 2) Measure info (see section 5.2

Strany 25 - Amplitude dB

6 4.1 Measure Controls RUN/PAUSE/CONTINUE When the user clicks this button, the measurement process is launched. The RUN button then automatically

Strany 26

7 4.3 Menu Bar File Menu Open Data: This item allows the user to open a measurement file (.rt6). Save Data: This item allows the user to save a mea

Komentáře k této Příručce

Žádné komentáře